1. Teb ceev: CBCT yog dab tsi?

2. CBCT Ua Li Cas?

3.CBCT ua haujlwm li cas? (Txoj Cai Ua Haujlwm)

4.CBCT siv rau dab tsi? (Key Applications)

5.CBCT vs Normal CT: Qhov txawv tseem ceeb

6.CBCT Cov Txheej Txheem Txhim Kho

7.Yuav xaiv txoj cai CBCT li cas? (Cov Lus Qhia Xaiv)

8.FULLSTAR: Koj Trusted CBCT Chaw Tsim Tshuaj & Chaw Muag Khoom

9. Cov lus nug nquag nug (FAQ)

 

Teb ceev
A Core BalanceTam sim no Transformer(CBCT) yog ib qho tshwj xeeb toroidal transformer siv los kuaj xyuas lub ntiaj teb to thiab av txhaum hauv cov tshuab hluav taws xob. Nws ua haujlwm los ntawm kev saib xyuas cov vector sum ntawm cov dej ntws los ntawm nws cov tub ntxhais. Nyob rau hauv tej yam kev mob, tus lej yog xoom; Thaum lub ntiaj teb ua txhaum, qhov tsis sib haum xeeb tsim cov seem tam sim no, ua rau muaj kev tiv thaiv relay mus rau lub voj voog.

Vim li cas thiaj xaiv CBCT zoo? Rau kev tiv thaiv txhim khu kev qha, ib txwm muab los ntawm cov kws tshaj lij CBCT cov chaw tsim khoom nrog ISO- ntawv pov thawj kev tswj hwm zoo thiab OEM muaj peev xwm kho tau.

 

CBCT Ua li cas?
CBCT sawv cev rau Core Balance Current Transformer. Nws kuj tau paub dav hauv kev lag luam raws li Zero Sequence Tam Sim No Transformer (ZSCT) lossis Residual Current Transformer. Cov ntsiab lus no feem ntau siv sib hloov hauv cov ntaub ntawv kev tshaj lij thiab phau ntawv tiv thaiv relay.

Kev nkag siab cov ntsiab lus no yog qhov tseem ceeb thaum tshawb nrhiav cov neeg muab khoom lossis sib piv CBCT cov khoom lag luam catalogs, vim cov cheeb tsam sib txawv yuav nyiam cov npe sib txawv.

 

CBCT ua haujlwm li cas? (Txoj Cai Ua Haujlwm)
Lub hauv paus ntsiab lus ua haujlwm ntawm CBCT yog nruj me ntsis raws li Kirchhoff Txoj Cai Tam Sim No thiab electromagnetic induction.

CBCT Schematic Normal vs Earth F
CBCT Txoj Cai Ua Haujlwm

✅ Ib txwm mob (Balanced State)
Hauv peb theem kev noj qab haus huv -theem (nrog lossis tsis muaj nruab nrab), phasor sum ntawm cov dej ntws los ntawm lub qhov rais CBCT yog xoom. Cov sib nqus fluxes tsim los ntawm txhua tus neeg xyuas pib tshem tawm, ua rau tsis muaj qhov tso tawm tam sim no mus rau lub relay.

⚠️ Lub Ntiaj Teb Fault Condition (Unbalanced State)
Thaum lub rwb thaiv tsev tsis ua haujlwm ua rau tam sim no xau rau hauv av (lub ntiaj teb txhaum), qhov rov qab tam sim no hla CBCT core. Qhov no tsim qhov seem tam sim no (zero-ib ntu tam sim no). Qhov tsis sib xws ua rau muaj qhov sib nqus sib nqus hauv lub toroidal core, inducing ib nrab tam sim no. Cov teeb liab no raug xa mus rau Lub Ntiaj Teb Fault Relay (EFR), uas pib qhov kev sib tw tripping.

📐 Daim Ntawv Ceeb Toom Ua Raws: FULLSTAR CBCTs yog tsim thiab sim ua raws li IEC 60044-1 thiab IEC 61869-2 cov qauv, ua kom ntseeg tau tias kev ua tau zoo hauv kev ua txhaum cai.

 

CBCT siv rau dab tsi? (Key Applications)
CBCTs yog qhov tseem ceeb hauv cov tshuab hluav taws xob niaj hnub no. Lawv lub siab rhiab heev rau cov dej ntws uas seem ua rau lawv haum rau cov ntawv thov tseem ceeb hauv qab no:

1. Ntiaj teb Fault Protection (Piv txwv)
CBCTs yog lub hauv paus tseem ceeb ntawm kev nkag siab hauv siab -kev tiv thaiv thiab qis- ua haujlwm hauv av. Lawv ntes cov dej xau tsawg li 30mA txog 5A, ua kom muaj kev sib cais ceev ceev.

 

2. Kev tiv thaiv lub cev muaj zog
Tiv thaiv nruab nrab thiab siab -voltage motor windings los ntawm stator hauv av faults. Txhua theem conductors dhau los ntawm CBCT, kom ntseeg tau tias tsuas yog qhov txhaum tam sim no ua rau muaj kev tiv thaiv.

 

3. Kev tiv thaiv kev hloov pauv
Tiv thaiv transformer tso tsheb hlau luam thiab windings los ntawm lub ntiaj teb ua txhaum, tiv thaiv kev puas tsuaj puas tsuaj los ntawm kev puas tsuaj thiab kev poob qis.

 

4. Cable Feeder tiv thaiv
Nruab ib ncig ntawm cable feeders los muab kev tiv thaiv kev ua txhaum hauv ntiaj teb. Tsuas yog faulty feeder mus txawv tebchaws, tswj fais fab mov mus rau tus so ntawm lub network.

 

5. Switchgear & MCC Vaj Huam Sib Luag
Ua kom cov neeg ua haujlwm muaj kev nyab xeeb thiab cov khoom siv ncaj ncees nyob rau hauv industrial switchgear thiab Motor Control Centers (MCCs).

 

6. Cov Kev Lag Luam Tshwj Xeeb

  • Data Centers: Tiv thaiv IT rhiab loads los ntawm cov dej xau.
  • Lub zog tauj dua tshiab (hnub ci / cua): Pom DC- sab thiab AC- sab hauv av ua txhaum.
  • Mining & Kev Lag Luam Hnyav: Ib puag ncig hnyav hnyav xav tau siab -rhiab heev, rugged CBCT designs.

 

CBCT vs Normal CT: Qhov txawv ntawm qhov tseem ceeb
Ib qho yuam kev feem ntau yog siv tus qauv CT rau kev kuaj xyuas lub ntiaj teb. Nov yog qhov kev sib piv tseem ceeb:

Feature Pauv CT CBCT (Core Balance CT)
Lub Hom Phiaj Phase tam sim no ntsuas / Overcurrent tiv thaiv Lub ntiaj teb fault & residual tam sim no nrhiav tau
Kev Ntsuas Object Tus kheej theem tam sim no Residual / Zero- ntu ntu tam sim no
Conductor Teeb Ib tug conductor rau ib tug core Txhua theem conductors dhau los ntawm tib lub hauv paus
Core Structure Ib tug thawj tig (busbar / cable) Toroidal core encircling tag nrho cov nyob conductors
Kev tiv thaiv Scope Tshaj dhau & luv -circuit Leakage & Av faults (siab rhiab heev)
Nqi Efficiency Txheem tus nqi Tus nqi siab dua vim muaj kev tiv thaiv tshwj xeeb
Conventional CT vs CBCT comparis
CBCT vs Normal CT Sib piv

💡 Tswv yim Engineering: Tsis txhob hloov CBCT nrog tus qauv CT rau kev tiv thaiv kev ua txhaum hauv av - qhov kev xav tau thiab kev teeb tsa yog qhov sib txawv.

 

CBCT Cov Txheej Txheem Txhim Kho
Kev txhim kho kom raug yog qhov tseem ceeb rau kev nrhiav kom raug. Ua raws li cov kev coj ua zoo tshaj plaws engineering:

  • Conductor Routing: Tag nrho peb theem conductors (thiab nruab nrab, yog tias tsim nyog) yuav tsum dhau qhov nruab nrab ntawm CBCT aperture.
  • Tsis suav nrog Lub Ntiaj Teb (Ground) Tus Cwj Pwm: Lub ntiaj teb tiv thaiv (PE) tus neeg xyuas pib yuav tsum tsis txhob hla CBCT. Ua li no yuav tshem tawm qhov teeb meem tam sim no.
  • Kev Ruaj Ntseg Cable: Xyuas kom cov cables ruaj ntseg ruaj ruaj los tiv thaiv kev txav mus los uas yuav ua rau kev nyeem ntawv tsis tseeb vim kev ntxhov siab ntawm cov neeg kho tshuab.
  • Relay Matching: CBCT cov thawj coj thib ob yuav tsum tau txuas nrog lub ntiaj teb Fault Relay (EFR). Xyuas kom lub nra relay (VA) phim CBCT specification.
  • Kev Tiv Thaiv Kev Tiv Thaiv: Khaws cov hlua txuas txuas txuas txuas ntxiv thiab tiv thaiv kom tsis txhob muaj hluav taws xob cuam tshuam los ntawm cov tsheb npav nyob ze.
    CBCT Installation Diagram
    CBCT Installation Diagram

Yuav Ua Li Cas Xaiv Txoj Cai CBCT? (Cov Lus Qhia Xaiv)
Kev xaiv CBCT txoj cai ua kom muaj kev tiv thaiv zoo thiab tus nqi - ua haujlwm tau zoo. Txawm hais tias koj yog ib tus kws tshaj lij qhia cov khoom siv lossis tus tub ceev xwm nrhiav kev hloov pauv CBCT, xav txog 5 qhov tseem ceeb no:

1. Inner Diameter (Qhov rai Loj)
Yuav tsum ua raws li tag nrho cov cables dhau los nrog kev tshem tawm txaus.

Qhov ntau thiab tsawg: 35mm, 70mm, 120mm, 210mm, 310mm.

Kev cai ntau thiab tsawg yog muaj los ntawm OEM manufacturers xws li XFULLSTAR.

2. Tam sim no rhiab heev (Primary Operating Current)
Txiav txim siab qhov tsawg kawg nkaus tam sim no uas yuav ua rau lub relay.

Kev teeb tsa ib txwm: 30mA (kev tiv thaiv neeg ua haujlwm) txog 5A (cov cuab yeej tiv thaiv).

3. Relay Compatibility (Tebchaws & Chaw)
Tshawb xyuas lub nra ntawm VA (piv txwv li, 2.5VA, 5VA) thiab qhov chaw relay teeb tsa tam sim no.

4. Chav kawm raug
Rau kev tiv thaiv daim ntawv thov, Chav Kawm 5P lossis 10P feem ntau txaus.

5. Ib puag ncig & Mounting
IP ntsuam xyuas (plua plav / dej tsis kam).

Kev khiav hauj lwm qhov kub thiab txias.

Mounting hom: Vaj huam sib luag mount, busbar mount, los yog phua-core.

 

FULLSTAR: Koj Trusted CBCT Chaw Tsim Tshuaj & Chaw Muag Khoom
Thaum muab qhov Core BalanceTam sim no Transformer, koom tes nrog cov chaw tsim khoom CBCT paub txog kev ntseeg tau, kev nyab xeeb, thiab kev ua haujlwm ntev -. XFULLSTAR sawv tawm raws li tus thawj coj CBCT tus neeg muag khoom muab kev daws teeb meem rau ntiaj teb kev lag luam thiab kev siv hluav taws xob.

🔧 Peb Kev Tsim Khoom & OEM Muaj Peev Xwm

  • Custom Dimensions: Peb tailor puab diameters thiab vaj tse tsim kom haum cov cim cable configurations.
  • Flexible Ratios: Customizable thawj rhiab heev tam sim no thiab cov zis theem nrab (piv txwv li, 1A lossis 5A).
  • Kev Pabcuam OEM / ODM: Peb tsim CBCTs raws li koj lub hom phiaj nrog koj cov ntawv tshwj xeeb thiab ntim cov cai.

✅ Quality Assurance

  • ISO 9001: 2015 tau ntawv pov thawj cov kab ntau lawm.
  • 100% kev xeem zaum kawg ua ntej xa tawm (kev xeem piv, kev xeem polarity, thiab kev ntsuas kev tiv thaiv hluav taws xob).
  • Ua raws li IEC 60044-1 thiab IEC 61869-2 cov qauv thoob ntiaj teb.

🏭 Kev Lag Luam Kev Lag Luam

  • Peb CBCTs tau siv dav hauv:
  • High-voltage switchgear panels
  • Cov chaw tiv thaiv lub cev muaj zog (MCPs)
  • Qhuav- hom thiab roj- puv transformers
  • Underground cable faib network
  • Lub zog tauj dua tshiab (photovoltaic & cua).

📞 Hu rau FULLSTAR rau CBCT kev daws teeb meem rau kev lag luam thiab kev tiv thaiv hluav taws xob. Peb muab cov nqi sib tw, xa khoom sai, thiab kev txhawb nqa kev txhawb nqa.

 

FAQ
Q1: Dab tsi yog tag nrho daim ntawv ntawm CBCT hauv cov tshuab hluav taws xob?
A: CBCT sawv cev rau Core Balance Current Transformer. Nws kuj tseem hu ua Zero Sequence Tam Sim No Transformer (ZSCT) txhawm rau txheeb xyuas cov seem seem.

Q2: Vim li cas CBCT siv tsis yog CT ib txwm ua rau lub ntiaj teb ua txhaum?
A: Ib txwm CT ntsuas tus kheej theem tam sim no, thaum CBCT pom cov vector sum ntawm txhua theem. Qhov no tso cai rau nws nkag siab txog cov dej ntws me me (mA ntau) uas tus qauv CTs tsis tuaj yeem ntes.

Q3: CBCT puas tuaj yeem kuaj xyuas theem-rau-theem faults?
A: Tsis yog. CBCTs tshwj xeeb yog tsim los rau lub ntiaj teb / hauv av txhaum. Theem-rau-phase faults yuav tsum muaj overcurrent lossis sib txawv tiv thaiv relays.

Q4: CBCT feem ntau ntsia qhov twg?
A: Hauv switchgear, MCC panels, transformer nruab nrab grounding, cable feeders, thiab lub cev muaj zog tswj circuits.

Q5: Leej twg yog CBCT cov chaw tsim khoom lossis tus neeg muag khoom txhim khu kev qha?
A: XFULLSTAR yog tus kws tshaj lij CBCT cov chaw tsim khoom muab siab -rhiab heev, kho tau, thiab IEC-raws li kev hloov pauv rau kev lag luam thiab kev siv hluav taws xob. Peb txhawb OEM tej yaam num thiab export thoob ntiaj teb.

Q6: Kuv yuav xaiv txoj cai CBCT li cas rau kuv qhov system?
A: Xav txog cov kab hluav taws xob (lub qhov rais sab hauv), xav tau rhiab heev (mA/A), relay lub nra (VA), thiab ib puag ncig tej yam kev mob. Xa mus rau peb Daim Ntawv Qhia Kev Xaiv saum toj no.